PARA Reny® 1012H

2018-09-05

Reny® 1012H      
Polyarylamide      
40% Glass Fiber      
Product Description
Reny® 1012H is a Polyarylamide (PARA) material filled with 40% glass fiber. It is available in Asia Pacific, Europe, or North America for injection molding. Primary attribute of Reny® 1012H: Flame Rated.
General  
Material Status  Commercial: Active
UL Yellow Card 2  E41179-231737
Filler / Reinforcement  Glass Fiber, 40% Filler by Weight
Processing Method  Injection Molding

 

Physical Dry Conditioned Unit Test Method
Density 1.56 -- g/cm³ ISO 1183
Melt Mass-Flow Rate (MFR) (275°C/2.16 kg) 22 -- g/10 min ISO 1133
Melt Volume-Flow Rate (MVR) (275°C/2.16 kg) 15.1 -- cm³/10min ISO 1133
Molding Shrinkage 0.42 -- %  
Water Absorption       ISO 62
Saturation, 23°C 0.18 -- %  
Equilibrium, 23°C, 50% RH 1.2 -- %  
Mechanical Dry Conditioned Unit Test Method
Tensile Modulus 16600 13600 MPa ISO 527-2
Tensile Stress (Break) 218 177 MPa ISO 527-2
Tensile Strain (Break) 1.8 1.8 % ISO 527-2
Flexural Modulus 14900 13800 MPa ISO 178
Flexural Stress 349 306 MPa ISO 178
Impact Dry Conditioned Unit Test Method
Charpy Notched Impact Strength (23°C) 8.5 8.9 kJ/m² ISO 179
Charpy Unnotched Impact Strength (23°C) 52 52 kJ/m² ISO 179
Thermal Dry Conditioned Unit Test Method
Heat Deflection Temperature        
0.45 MPa, Unannealed 237 232 °C ISO 75-2/B
1.8 MPa, Unannealed 226 218 °C ISO 75-2/A
CLTE       ISO 11359-2
Flow  2.00E-05 -- cm/cm/°C  
Transverse  5.00E-05 -- cm/cm/°C  
Flammability Dry Conditioned   Test Method
Flame Rating (1.60 mm) HB --   UL 94
Injection Dry Unit    
Drying Temperature        
120 °C    
80 °C    
Drying Time        
> 3.0 hr    
> 12 hr    
Rear Temperature 270 °C    
Middle Temperature 275 °C    
Front Temperature 280 °C    
Nozzle Temperature 280 °C    
Mold Temperature 120 to 140 °C    
Injection Pressure 20.0 to 150 MPa    
Injection Rate Moderate-Fast      
Screw Speed 60 to 150 rpm    